CDM-based closed-loop transfer function design for ramp input.
- Source :
-
Transactions of the Institute of Measurement & Control . Jul2011, Vol. 33 Issue 5, p558-572. 15p. 1 Diagram, 8 Graphs. - Publication Year :
- 2011
-
Abstract
- This paper presents a method to determine the denominator and numerator polynomials of a closed-loop transfer function in order to obtain desired transient and steady-state responses in terms of the overshoot, speed (time needed for the relative error to become less than a specific amount) and the steady-state error when the desired output is a ramp signal. Meanwhile, a controller is designed with the same characteristic equation for the closed-loop system to eliminate step and ramp disturbances. [ABSTRACT FROM AUTHOR]