Back to Search Start Over

Measurement of Poisson’s ratio by means of a direct tension test on micron-sized specimens

Authors :
Banks-Sills, Leslie
Hikri, Yael
Krylov, Slava
Fourman, Victor
Gerson, Yuval
Bruck, Hugh A.
Source :
Sensors & Actuators A: Physical. Sep2011, Vol. 169 Issue 1, p98-114. 17p.
Publication Year :
2011

Abstract

Abstract: A methodology developed for measuring Young’s modulus and the full stress–strain curve on micron-sized specimens was extended here to measure Poisson’s ratio. A dog-bone type specimen was used within a small loading machine with a maximum load of 5N. The specimen was fabricated from single crystal silicon (SC-Si) with the specimen gage and loading direction in the 〈001〉 orientation. A silicon on insulator (SOI) wafer was used with a deep reactive ion etching (DRIE) based process. Geometrical parameters of the initial cross-sectional area of the gage were measured by means of image processing on environmental scanning electron microscope (ESEM) images. The test setup also consists of an optical microscope with a monochromatic camera and a data acquisition system. The strains were obtained through the displacement field which was determined by means of digital image correlation (DIC). A speckle pattern was placed on the specimen gage. SC-Si was chosen to study since it is expected that on both the micro and macro-scales, Young’s modulus and Poisson’s ratio will have the same value. Hence, the accuracy of the method may be examined. The average value of Young’s modulus E =131.4±2.1GPa was obtained with the micro-specimens and is consistent with values determined on the macro-scale (E =130GPa). The average value of Poisson’s ratio on the micro-scale was found as ν =0.23±0.03 which is lower than the macro-scale value of ν =0.28. The failure stress was determined to be σ f =1.46±0.10GPa. Results for Young’s modulus reflect the reliability of the methodology which is suitable for characterization of a large variety of materials exploited in micro-devices for both sensing and actuation. The reasons for the low values measured for ν were investigated through emulations of determining the strains. An improvement in the image acquisition system is suggested. [Copyright &y& Elsevier]

Details

Language :
English
ISSN :
09244247
Volume :
169
Issue :
1
Database :
Academic Search Index
Journal :
Sensors & Actuators A: Physical
Publication Type :
Academic Journal
Accession number :
61920159
Full Text :
https://doi.org/10.1016/j.sna.2011.04.030