Back to Search
Start Over
ISOLATION AND DETERMINATION OF 4-BIPHENYLAMINE FOR AIR SAMPLE BY SPE-HPLC COUPLING.
- Source :
-
Journal of Liquid Chromatography & Related Technologies . 2011, Vol. 34 Issue 6, p397-407. 11p. - Publication Year :
- 2011
-
Abstract
- The method of determination of 4-biphenylamine (4-BA) in workplace air using SPE and HPLC has been presented. The method consists in passing the air that contains 4-BA through a glass fiber filter with sulfuric acid placed on it, washing out the substance settled on the filter, using water and a solution of sodium hydroxide, solid phase extraction (SPE) in order to enrich the analyte, replace the dissolvent with methanol, and analyze the obtained solution using a method of highly efficient liquid chromatography with fluorescent detection (λex = 268 nm, λem = 389 nm). Measuring range for the 100 dm3 air sample was: 0.1-2 μg/m3. Limit of detection (LOD) and limit of quantification (LOQ) were 0.18 ng/m3 and 0.54 ng/m3, respectively. [ABSTRACT FROM AUTHOR]
Details
- Language :
- English
- ISSN :
- 10826076
- Volume :
- 34
- Issue :
- 6
- Database :
- Academic Search Index
- Journal :
- Journal of Liquid Chromatography & Related Technologies
- Publication Type :
- Academic Journal
- Accession number :
- 59530587
- Full Text :
- https://doi.org/10.1080/10826076.2011.547065