Back to Search Start Over

Measurement of isobaric heat capacity of R125

Authors :
Kagawa, Noboru
Matsuguchi, Atsushi
Watanabe, Koichi
Source :
International Journal of Refrigeration. Jan2011, Vol. 34 Issue 1, p275-279. 5p.
Publication Year :
2011

Abstract

Abstract: The specific isobaric heat capacity (cp ) was measured for R125 (pentafluoroethane) in the gas phase by using a flow calorimeter. Twelve measurements for R125 were obtained at temperatures from 313 to 333K and at pressures from 0.8 to 2.4MPa. Some of them are close to the saturation curve. The expanded uncertainty (k =2) of the temperature measurements is estimated to be less than 23mK, and that of the pressure measurements is less than 14kPa. The expanded uncertainty for cp is estimated to range from 12 to 22Jkg−1 K−1. Also, the experimental data were compared with available equations of state. From the results, it became clear that these data will be essential to improve available models so as to represent more reliable thermodynamic properties of R125 and refrigerant mixtures with R125 that are used for refrigeration and air conditioning systems. [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
01407007
Volume :
34
Issue :
1
Database :
Academic Search Index
Journal :
International Journal of Refrigeration
Publication Type :
Academic Journal
Accession number :
55727457
Full Text :
https://doi.org/10.1016/j.ijrefrig.2010.08.009