Back to Search
Start Over
Study on critical current distribution in CT-OP Bi-2223 tape based on the scanning Hall probe magnetic microscopy
- Source :
-
Physica C . Nov2010, Vol. 470 Issue 20, p1377-1379. 3p. - Publication Year :
- 2010
-
Abstract
- Abstract: Critical current (I c) of a Bi-2223 tape fabricated by controlled-overpressure (CT-OP) sintering method has been attained up to 200 A-class in recent years. However, current limiting factors have not been fully clarified yet. In this study, we have investigated local current distributions in a CT-OP Bi-2223 tape by using the scanning Hall probe magnetic microscopy. As a result, it has been found that large sheet current flows in the center of the sample. Even though the influence of self-field is taken into account, there is a clear difference of local I c across the width. The maximum sheet current value in the center of the tape is 400–450A/cm when we applied the bias current of 100A, which is equal to the I c at around 87K. This value is equivalent to 800–900A/cm at 77K taking into account the value of I c. Furthermore, such current distribution continues uniformly in length direction. From these results, we have concluded that improvement of current uniformity across the tape width is the effective way to enhance critical current for the present CT-OP Bi-2223 tape. Our results show the feasibility for 300 A-class I c at 77K. [ABSTRACT FROM AUTHOR]
Details
- Language :
- English
- ISSN :
- 09214534
- Volume :
- 470
- Issue :
- 20
- Database :
- Academic Search Index
- Journal :
- Physica C
- Publication Type :
- Academic Journal
- Accession number :
- 53334998
- Full Text :
- https://doi.org/10.1016/j.physc.2010.05.117