Back to Search
Start Over
Measurement of Small-Signal Gain on COIL with Chemically Generated Molecular Iodine.
- Source :
-
IEEE Journal of Quantum Electronics . Sep2010, Vol. 46 Issue 9, p1350-1353. 4p. - Publication Year :
- 2010
-
Abstract
- A chemical gas-phase reaction between CI2 and HI was used in the generation of molecular iodine for the chemical oxygen--iodine laser (COIL) operation. A yield of I2 in the generation reaction up to 85% was achieved in a reasonable volume of the reactor. A small-signal gain up to 0.75%/cm at a temperature of 150K in the center of supersonic cavity was measured. A comparison with the established evaporation way of I2 delivery confirmed that the chemical method has little or no impact on the COIL pumping kinetics. This chemical method is easily scalable and can simplify the COIL operation by providing better control of I2 flow rate. [ABSTRACT FROM AUTHOR]
- Subjects :
- *IODINE lasers
*MOLECULES
*EVAPORATION (Chemistry)
*GASES
*IODINE
Subjects
Details
- Language :
- English
- ISSN :
- 00189197
- Volume :
- 46
- Issue :
- 9
- Database :
- Academic Search Index
- Journal :
- IEEE Journal of Quantum Electronics
- Publication Type :
- Academic Journal
- Accession number :
- 52848583
- Full Text :
- https://doi.org/10.1109/JQE.2010.2048555