Back to Search Start Over

Sequential Probability Ratio Test Using Scaled Time-Intervals for Environmental Radiation Monitoring.

Authors :
Peng Luo
DeVol, Timothy A.
Sharp, Julia L.
Source :
IEEE Transactions on Nuclear Science. Jun2010 Part 3 of 3, Vol. 57 Issue 3, p1556-1562. 7p.
Publication Year :
2010

Abstract

Sequential probability ratio test (SPRT) of scaled time-interval data (time to record N radiation pulses), SPRT_scaled, was evaluated against commonly used single-interval test (SIT) and SPRT with a fixed counting interval, SPRT_fixed, on experimental and simulated data. Experimental data were acquired with a DGF-4C (XIA, Inc) system in list mode. Simulated time-interval data were obtained using Monte Carlo techniques to perform a random radiation sampling of the Poisson distribution. The three methods (SIT, SPRT_fixed and SPRT_scaled) were compared in terms of detection probability and average time to make a decision regarding the source of radiation. For both experimental and simulated data, SPRT_scaled provided similar detection probabilities as other tests, but was able to make a quicker decision with fewer pulses at relatively higher radiation levels. SPRT_scaled has a provision for varying the sampling time depending on the radiation level, which may further shorten the time needed for radiation monitoring. Parameter adjustments to the SPRT_scaled method for increased detection probability are discussed. [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
00189499
Volume :
57
Issue :
3
Database :
Academic Search Index
Journal :
IEEE Transactions on Nuclear Science
Publication Type :
Academic Journal
Accession number :
51675317
Full Text :
https://doi.org/10.1109/TNS.2010.2045900