Back to Search
Start Over
PD Apparent Charge Estimation and Calibration: a Critical Review.
- Source :
-
IEEE Transactions on Dielectrics & Electrical Insulation . Feb2010, Vol. 17 Issue 1, p198-205. 8p. - Publication Year :
- 2010
-
Abstract
- This paper focuses on the limits of partial discharge apparent charge estimation and calibration using an unified approach. The fundamental problems that prevent accurate apparent charge estimates (resonances, attenuation and partial discharge pulse splitting) are tackled through this approach, highlighting the physical limitations that prevent partial discharge charge to be measured properly. The feasibility of calibration of Ultra-Wide Bandwidth measurement systems, something that is not treated in the IEC 60270 standard, is also discussed. [ABSTRACT FROM AUTHOR]
Details
- Language :
- English
- ISSN :
- 10709878
- Volume :
- 17
- Issue :
- 1
- Database :
- Academic Search Index
- Journal :
- IEEE Transactions on Dielectrics & Electrical Insulation
- Publication Type :
- Academic Journal
- Accession number :
- 48612748
- Full Text :
- https://doi.org/10.1109/TDEI.2010.5412018