Simultaneous online measurement of sulfide and nitrate in sewers for nitrate dosage optimisation.

Authors :
Gutierrez, Oriol
Sutherland-Stacey, Luke
Zhiguo Yuan
Source :
Water Science & Technology. 2010, Vol. 61 Issue 3, p651-658. 8p. 1 Diagram, 2 Charts, 4 Graphs.
Publication Year :
2010

Abstract

A new method for the simultaneous online measurement of sulfide and nitrate in wastewater is developed. A UV-VIS spectrometer was used. The sensor was calibrated by means of simultaneous online and offline measurements of sulfide and nitrate in batch tests carried out on a laboratory-scale sewer system. The developed calibration algorithm was successfully validated for both sulfide and nitrate measurement, with confidence limits of 2.7 mg S/L for total dissolved sulfide, and 7.5 mg N/L for nitrate. The online measurement of sulfide and nitrate enabled detailed evaluation of seven nitrate dosing strategies in the laboratory-scale sewer system, providing strong support to process optimisation. The dosage optimisation revealed that nitrate should be added at a location close to the point of sulfide control rather than at the beginning of a rising main, at a rate proportional to the expected hydraulic retention time (HRT) of the wastewater in the sewer section between the point of nitrate addition and the point where sulfide control is desired. [ABSTRACT FROM AUTHOR]