Development of SciFi/CheFi detector with SiPM readout

Authors :
Suzuki, Ken
Bühler, Paul
Fossati, Stefan
Marton, Johann
Schafhauser, Matthias
Zmeskal, Johann
Source :
Nuclear Instruments & Methods in Physics Research Section A. Oct2009, Vol. 610 Issue 1, p75-77. 3p.
Publication Year :
2009

Abstract

Abstract: A Multi-pixel Geiger-mode APD, often called a Silicon Photomultiplier (SiPM), is a new type of photon counting device made up of multiple APD pixels operated in the Geiger-mode, which started to replace the PMT in a certain parts of photodetection field. Stefan Meyer Institute in Vienna has been working on an evaluation of several kinds of SiPMs from different manufacturers with different sizes of cells, sensitive area. We operate SiPMs in combination with scintillating fiber and Cherenkov radiator to test its potential with special focus on its timing performance, compactness and low-cost. The detectors are going to be applied in experiments like FOPI, AMADEUS and PANDA. [Copyright &y& Elsevier]

Details

Language :
English
ISSN :
01689002
Volume :
610
Issue :
1
Database :
Academic Search Index
Journal :
Nuclear Instruments & Methods in Physics Research Section A
Publication Type :
Academic Journal
Accession number :
45138815
Full Text :
https://doi.org/10.1016/j.nima.2009.05.074