Back to Search
Start Over
Differences in Restenosis Rate With Different Drug-Eluting Stents in Patients With and Without Diabetes Mellitus: A Report From the SCAAR (Swedish Angiography and Angioplasty Registry)
- Source :
-
Journal of the American College of Cardiology (JACC) . May2009, Vol. 53 Issue 18, p1660-1667. 8p. - Publication Year :
- 2009
-
Abstract
- Objectives: Our aim was to evaluate restenosis rate of drug-eluting stents (DES) in patients with and without diabetes mellitus (DM) in a real-world setting. Background: DES seem less effective in patients with DM. Methods: The SCAAR (Swedish Coronary Angiography and Angioplasty Registry) includes all patients undergoing percutaneous coronary intervention in Sweden. From April 1, 2004, to April 20, 2008, all restenoses detected at a subsequent angiography and all DES types implanted at more than 500 occasions were assessed using Cox regression. Results: Four DES types qualified for inclusion. In total, 35,478 DES were implanted at 22,962 procedures in 19,004 patients and 1,807 restenoses were reported over a mean 29 months follow-up. In the entire population, the restenosis rate per stent was 3.5% after 1 year and 4.9% after 2 years. The adjusted risk of restenosis was higher in patients with DM compared with that in patients without DM (relative risk [RR]: 1.23, 95% confidence interval [CI]: 1.10 to 1.37). In patients with DM, restenosis was twice as frequent with the zotarolimus-eluting Endeavor stent (Medtronic, Minneapolis, Minnesota) compared with that in the other DES types. The Endeavor stent and the sirolimus-eluting Cypher stent (Cordis, Johnson & Johnson, Miami, Florida) had higher restenosis rates in patients with DM compared with those in patients without DM (RR: 1.77, 95% CI: 1.29 to 2.43 and RR: 1.25, 95% CI: 1.04 to 1.51). Restenosis rate with the paclitaxel-eluting Taxus Express and Liberté (Boston Scientific, Natick, Massachusetts) stents was unrelated to DM. Mortality did not differ between different DES. Conclusions: Restenosis rate with DES was higher in patients with DM compared with that in patients without DM. There seem to be important differences between different brands of DES. [Copyright &y& Elsevier]
Details
- Language :
- English
- ISSN :
- 07351097
- Volume :
- 53
- Issue :
- 18
- Database :
- Academic Search Index
- Journal :
- Journal of the American College of Cardiology (JACC)
- Publication Type :
- Academic Journal
- Accession number :
- 38805053
- Full Text :
- https://doi.org/10.1016/j.jacc.2009.01.054