Back to Search Start Over

Behaviour of helium after implantation in molybdenum

Authors :
Viaud, C.
Maillard, S.
Carlot, G.
Valot, C.
Gilabert, E.
Sauvage, T.
Peaucelle, C.
Moncoffre, N.
Source :
Journal of Nuclear Materials. Mar2009, Vol. 385 Issue 2, p294-298. 5p.
Publication Year :
2009

Abstract

Abstract: This study deals with the behaviour of helium in a molybdenum liner dedicated to the retention of fission products. More precisely this work contributes to evaluate the release of implanted helium when the gas has precipitated into nanometric bubbles close to the free surface. A simple model dedicated to calculate the helium release in such a condition is presented. The specificity of this model lays on the assumption that the gas is in equilibrium with a simple distribution of growing bubbles. This effort is encouraging since the calculated helium release fits an experimental dataset with a set of parameters in good agreement with the literature. [Copyright &y& Elsevier]

Details

Language :
English
ISSN :
00223115
Volume :
385
Issue :
2
Database :
Academic Search Index
Journal :
Journal of Nuclear Materials
Publication Type :
Academic Journal
Accession number :
36973441