Back to Search Start Over

A line-of-sight electron cyclotron emission receiver for electron cyclotron resonance heating feedback control of tearing modes.

Authors :
Oosterbeek, J. W.
Bürger, A.
Westerhof, E.
de Baar, M. R.
van den Berg, M. A.
Bongers, W. A.
Graswinckel, M. F.
Hennen, B. A.
Kruijt, O. G.
Thoen, J.
Heidinger, R.
Korsholm, S. B.
Leipold, F.
Nielsen, S. K.
Source :
Review of Scientific Instruments. Sep2008, Vol. 79 Issue 9, p093503. 12p. 4 Diagrams, 1 Chart, 11 Graphs.
Publication Year :
2008

Abstract

An electron cyclotron emission (ECE) receiver inside the electron cyclotron resonance heating (ECRH) transmission line has been brought into operation. The ECE is extracted by placing a quartz plate acting as a Fabry–Perot interferometer under an angle inside the electron cyclotron wave (ECW) beam. ECE measurements are obtained during high power ECRH operation. This demonstrates the successful operation of the diagnostic and, in particular, a sufficient suppression of the gyrotron component preventing it from interfering with ECE measurements. When integrated into a feedback system for the control of plasma instabilities this line-of-sight ECE diagnostic removes the need to localize the instabilities in absolute coordinates. [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
00346748
Volume :
79
Issue :
9
Database :
Academic Search Index
Journal :
Review of Scientific Instruments
Publication Type :
Academic Journal
Accession number :
34647340
Full Text :
https://doi.org/10.1063/1.2976665