Back to Search Start Over

Long-term follow-up of supra-annular pulmonary autograft aortic root replacement in patients with bicuspid aortic valve

Authors :
Özaslan, Feyzan
Wittlinger, Thomas
Monsefi, Nadejna
Bouhmidi, Tamimount
Theres, Sinthu
Doss, Mirko
Wimmer-Greinecker, Gerhard
Moritz, Anton
Source :
European Journal of Cardio-Thoracic Surgery. Sep2008, Vol. 34 Issue 3, p583-588. 6p.
Publication Year :
2008

Abstract

Abstract: Objective: The performance of the Ross procedure in the case of geometric mismatch between pulmonary autograft and a bicuspid aortic root has not yet been fully evaluated. To prevent geometrically caused autograft dysfunction, a modification of the surgical technique is necessary. Methods: Between January 1996 and January 2007, 50 patients (33 male, 17 female; mean age 50±14 years; range 13–63 years) underwent replacement of a diseased bicuspid aortic valve (stenosis in 14 cases; insufficiency in 21; combined disease in 15) with a Ross procedure. The pulmonary autograft was inserted partially in supra-annular position to correct the geometric mismatch between the deeper base of the non-coronary sinus and the right/left coronary sinus. In 24 of these patients, additional tailoring of the non-coronary sinus was necessary. In eight patients the non-coronary sinus was covered with a glutaraldehyde treated autologous pericardial patch to prevent pseudoaneurysm formation. Patients were followed up 1, 2, 5 and 10 years postoperatively. Results: There were no early or late deaths. There were six reoperations. One patient was reoperated because of persistent severe aortic valve insufficiency 9 months postoperatively. Three patients were reoperated for formation of subannular pseudoaneurysm, 6, 9 and 30 months postoperatively. One patient was reoperated for closure of a paravalvular dehiscence. Another patient was reoperated 1 year postoperatively because of a severe pulmonary stenosis due to excessive calcification of the bioprosthesis. Echocardiographic follow-up of the remaining patients showed no evidence of residual or recurrent pulmonary autograft regurgitation or progression of aortic root dilatation. Conclusion: Autograft replacement of the bicuspid aortic valve is challenging, as the geometric mismatch has to be adjusted. Valve dysfunction is avoided by a supra-annular implantation technique, but pseudoaneurysm formation at the base of the non-coronary sinus is a worrying aspect. Patch reinforcement may solve this issue. [Copyright &y& Elsevier]

Details

Language :
English
ISSN :
10107940
Volume :
34
Issue :
3
Database :
Academic Search Index
Journal :
European Journal of Cardio-Thoracic Surgery
Publication Type :
Academic Journal
Accession number :
33887343
Full Text :
https://doi.org/10.1016/j.ejcts.2008.05.056