To monitor tableting production using near infrared (NIR) spectroscopy, chemometric models were developed to analyze peak compression force, crushing strength and content uniformity. To measure tablet content uniformity, orbifloxacin tablets with drug content ranging from 60 to 90 mg were made and analyzed using ultraviolet (UV) and NIR spectroscopy. To assess the compression force and crushing strength, several batches of tablets were made on a Stokes B2 rotary tablet press and compression force was varied from 360 to 3500 lb. Principal component analysis (PCA) was used to identify tablets with regular and capped tablets breakage patterns. Comparison of statistical parameters showed that partial least squares (PLS) models gave better fit than the multiple linear regression (MLR) models. The best fit PLS models had a standard error of calibration (SEC) and a standard error of prediction (SEP) for content uniformity of 1.13 and 1.36 mg; for compression force of 69.86 and 59.48 lb and for crushing strength 0.55 kP and 0.57 kP, respectively. NIR spectroscopy in combination with multivariate modeling is a rapid and nondestructive technique that could reliably predict content uniformity, compression force and crushing strength for orbifloxacin tablets. © 2008 Wiley-Liss, Inc. and the American Pharmacists Association J Pharm Sci 97:4040–4051, 2008 [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
00223549
Volume :
97
Issue :
9
Database :
Academic Search Index
Journal :
Journal of Pharmaceutical Sciences
Publication Type :
Academic Journal
Accession number :
33468083
Full Text :
https://doi.org/10.1002/jps.21303