Back to Search Start Over

Comparison of manual direct and automated indirect measurement of hippocampus using magnetic resonance imaging

Authors :
Giesel, Frederik L.
Thomann, Philipp A.
Hahn, Horst K.
Politi, Maria
Stieltjes, Bram
Weber, Marc-André
Pantel, Johannes
Wilkinson, I.D.
Griffiths, Paul D.
Schröder, Johannes
Essig, Marco
Source :
European Journal of Radiology. May2008, Vol. 66 Issue 2, p268-273. 6p.
Publication Year :
2008

Abstract

Abstract: Purpose: Objective quantification of brain structure can aid diagnosis and therapeutic monitoring in several neuropsychiatric disorders. In this study, we aimed to compare direct and indirect quantification approaches for hippocampal formation changes in patients with mild cognitive impairment and Alzheimer''s disease (AD). Methods and materials: Twenty-one healthy volunteers (mean age: 66.2), 21 patients with mild cognitive impairment (mean age: 66.6), and 10 patients with AD (mean age: 65.1) were enrolled. All subjects underwent extensive neuropsychological testing and were imaged at 1.5T (Vision, Siemens, Germany; T1w coronal TR=4ms, Flip=13°, FOV=250mm, Matrix=256×256, 128 contiguous slices, 1.8mm). Direct measurement of the hippocampal formation was performed on coronal slices using a standardized protocol, while indirect temporal horn volume (THV) was calculated using a watershed algorithm-based software package (MeVis, Germany). Manual tracing took about 30min, semi-automated measurement less than 3min time. Results: Successful direct and indirect quantification was performed in all subjects. A significant volume difference was found between controls and AD patients (p <0.001) with both the manual and the semi-automated approach. Group analysis showed a slight but not significant decrease of hippocampal volume and increase in temporal horn volume (THV) for subjects with mild cognitive impairment compared to volunteers (p <0.07). A significant correlation (p <0.001) of direct and indirect measurement was found. Conclusion: The presented indirect approach for hippocampus volumetry is equivalent to the direct approach and offers the advantages of observer independency, time reduction and thus usefulness for clinical routine. [Copyright &y& Elsevier]

Details

Language :
English
ISSN :
0720048X
Volume :
66
Issue :
2
Database :
Academic Search Index
Journal :
European Journal of Radiology
Publication Type :
Academic Journal
Accession number :
31920097
Full Text :
https://doi.org/10.1016/j.ejrad.2007.06.009