Back to Search Start Over

A Randomized Comparison of Triple-Site Versus Dual-Site Ventricular Stimulation in Patients With Congestive Heart Failure

Authors :
Leclercq, Christophe
Gadler, Fredrik
Kranig, Wolfgang
Ellery, Sue
Gras, Daniel
Lazarus, Arnaud
Clémenty, Jacques
Boulogne, Eric
Daubert, Jean-Claude
Source :
Journal of the American College of Cardiology (JACC). Apr2008, Vol. 51 Issue 15, p1455-1462. 8p.
Publication Year :
2008

Abstract

Objectives: We compared the effects of triple-site versus dual-site biventricular stimulation in candidates for cardiac resynchronization therapy. Background: Conventional biventricular stimulation with a single right ventricular (RV) and a single left ventricular (LV) lead is associated with persistence of cardiac dyssynchrony in up to 30% of patients. Methods: This multicenter, single-blind, crossover study enrolled 40 patients (mean age 70 ± 9 years) with moderate-to-severe heart failure despite optimal drug treatment, a mean LV ejection fraction of 26 ± 11%, and permanent atrial fibrillation requiring cardiac pacing for slow ventricular rate. A cardiac resynchronization therapy device connected to 1 RV and 2 LV leads, inserted in 2 separate coronary sinus tributaries, was successfully implanted in 34 patients. After 3 months of biventricular stimulation, the patients were randomly assigned to stimulation for 3 months with either 1 RV and 2 LV leads (3-V) or to conventional stimulation with 1 RV and 1 LV lead (2-V), then crossed over for 3 months to the alternate configuration. The primary study end point was quality of ventricular resynchronization (Z ratio). Secondary end points included reverse LV remodeling, quality of life, distance covered during 6-min hall walk, and procedure-related morbidity and mortality. Data from the 6- and 9-month visits were combined to compare end points associated with 2-V versus 3-V. Results: Data eligible for protocol-defined analyses were available in 26 patients. No significant difference in Z ratio, quality of life, and 6-min hall walk was observed between 2-V and 3-V. However, a significantly higher LV ejection fraction (27 ± 11% vs. 35 ± 11%; p = 0.001) and smaller LV end-systolic volume (157 ± 69 cm3 vs. 134 ± 75 cm3; p = 0.02) and diameter (57 ± 12 mm vs. 54 ± 10 mm; p = 0.02) were observed with 3-V than with 2-V. There was a single minor procedure-related complication. Conclusions: Cardiac resynchronization therapy with 1 RV and 2 LV leads was safe and associated with significantly more LV reverse remodeling than conventional biventricular stimulation. [Copyright &y& Elsevier]

Details

Language :
English
ISSN :
07351097
Volume :
51
Issue :
15
Database :
Academic Search Index
Journal :
Journal of the American College of Cardiology (JACC)
Publication Type :
Academic Journal
Accession number :
31677962
Full Text :
https://doi.org/10.1016/j.jacc.2007.11.074