Back to Search Start Over

Modified method of high alternating current measurement.

Authors :
Bera, S. C.
Kole, D. N.
Mandal, M.
Source :
IET Science, Measurement & Technology (Institution of Engineering & Technology). May2008, Vol. 2 Issue 3, p107-113. 7p. 1 Diagram, 3 Graphs.
Publication Year :
2008

Abstract

The conventional current transformers (CTs) in the form of a bar primary and secondary winding on a highly permeable ring core suffer from ratio error and phase angle errors, which are primarily due to the no-load current of the transformer. A modified design of a CT has been described. In this design, a feedback technique has been used in order to reduce the no-load current to a negligibly small value so that the said error may be minimal. Using this technique, a CT has been designed and fabricated with the commercially available material. The performance of the transformer has been tested experimentally and the output and input AC waves have been observed in a storage cathode ray oscilloscope (CRO) and the experimental results are reported. [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
17518822
Volume :
2
Issue :
3
Database :
Academic Search Index
Journal :
IET Science, Measurement & Technology (Institution of Engineering & Technology)
Publication Type :
Academic Journal
Accession number :
31229993
Full Text :
https://doi.org/10.1049/iet-smt:20070029