Back to Search Start Over

Theoretical and electrophysiological evidence for axial loading about aortic baroreceptor nerve terminals in rats.

Authors :
Bin Feng
Bai-yan Li
Nauman, Eric A.
Schild, John H.
Source :
American Journal of Physiology: Heart & Circulatory Physiology. Dec2007, Vol. 293 Issue 6, pH3659-H3672. 14p. 5 Diagrams, 1 Chart, 5 Graphs.
Publication Year :
2007

Abstract

Arterial baroreceptors are essential for neurocirculatory control, providing rapid hemodynamic feedback to the central nervous system. The pressure-dependent discharge of carotid and aortic baroreceptor afferents has been extensively studied. A common assumption has been that circumferential deformation of the arterial wall is the predominant mechanical force affecting baroreceptor discharge. However, in vivo the arterial tree is under significant longitudinal tension, leading to the hypothesis that axially directed forces may contribute to baroreceptor function. To test this hypothesis, we utilized a combination of finite element modeling methods and an in vitro rat aortic arch preparation. Model formulation utilized traditional analytic constructs available in the literature followed by refinement of model material parameters through direct comparison of computationally and experimentally generated pressure-diameter curves. The numerical simulations strongly indicated a functional role for axial loading within the region of the baroreceptive nerve terminal. This prediction was confirmed through single-fiber recording of baroreceptor nerve discharge under conditions with and without longitudinal tension in the vessel preparation. The recordings (n = 5) demonstrated that longitudinal tension significantly (P < 0.02) lowered both the pressure threshold (Pth, mmHg) for baroreceptor discharge and sensitivity (Sth, Hz/mmHg). The effect was nearly instantaneous and sustained; i.e., under longitudinal tension average Pth was 84 ± 3 mmHg and So, was 0.71 ± 0.15 Hz/mmHg, which immediately increased to a Pth of 94 ± 4 mmHg and a Sth of 1.20 ± 0.32 Hz/mmHg with loss of axial tension. Possible explanations of how an abrupt change in axial loading could result in a synchronized increase in afferent drive of the baroreceptor reflex, and the potentiating effect this could have on neurogenically mediated orthostatic intolerance are discussed. [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
03636135
Volume :
293
Issue :
6
Database :
Academic Search Index
Journal :
American Journal of Physiology: Heart & Circulatory Physiology
Publication Type :
Academic Journal
Accession number :
28047719
Full Text :
https://doi.org/10.1152/ajpheart.00712.2007