Back to Search Start Over

Unbalanced Magnetic Forces in Permanent-Magnet Brushless Machines With Diametrically Asymmetric Phase Windings.

Authors :
Zhu, Z. Q.
Ishak, Dahaman
Howe, David
Jintao Chen
Source :
IEEE Transactions on Industry Applications. Nov/Dec2007, Vol. 43 Issue 6, p1544-1553. 10p.
Publication Year :
2007

Abstract

A general analytical model, formulated in 2-D polar coordinates, is developed to predict the unbalanced magnetic force, which results in permanent-magnet brushless ac and dc machines having a diametrically asymmetric disposition of slots and phase windings. It is shown that the unbalanced magnetic force can be significant in machines having a fractional ratio of slot number to pole number, particularly when the electric loading is high. The developed model is validated by finite-element calculations on 9-slot/8-pole and 3-slot/2-pole machines. In addition, the unbalanced magnetic force has been measured on a prototype 3-slot/2-pole machine and shown to be in excellent agreement with predicted results. [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
00939994
Volume :
43
Issue :
6
Database :
Academic Search Index
Journal :
IEEE Transactions on Industry Applications
Publication Type :
Academic Journal
Accession number :
27775439
Full Text :
https://doi.org/10.1109/TIA.2007.908158