Back to Search Start Over

Qualification tests of the 11000 photomultipliers for the Pierre Auger Observatory fluorescence detectors

Authors :
Becker, K.-H.
Behrmann, A.
Bracci, F.
Delle Fratte, C.
Facal San Luis, P.
Fontaine, Ch.
Geenen, H.
Guérin, D.
Hartmann, S.
Kampert, K.-H.
Lavoute, P.
Matthiae, G.
Petrinca, P.
Privitera, P.
Rodriguez Martino, J.
Salina, G.
Scherini, V.
Verzi, V.
Weischer, U.
Wiebusch, Ch.
Source :
Nuclear Instruments & Methods in Physics Research Section A. Jun2007, Vol. 576 Issue 2/3, p301-311. 11p.
Publication Year :
2007

Abstract

Abstract: We describe the test system built to perform the acceptance tests of more than 11000 photomultiplier (PMT) tubes employed in the fluorescence detector of the Pierre Auger Observatory. The results obtained on the properties of the PMT are presented and discussed. [Copyright &y& Elsevier]

Details

Language :
English
ISSN :
01689002
Volume :
576
Issue :
2/3
Database :
Academic Search Index
Journal :
Nuclear Instruments & Methods in Physics Research Section A
Publication Type :
Academic Journal
Accession number :
25104636
Full Text :