Back to Search
Start Over
High-rate photon counting and picosecond timing with silicon-SPAD based compact detector modules.
- Source :
-
Journal of Modern Optics . 1/20/2007, Vol. 54 Issue 2/3, p225-237. 13p. 1 Black and White Photograph, 1 Diagram, 1 Chart, 10 Graphs. - Publication Year :
- 2007
-
Abstract
- New detector modules exploit recent progress in the technology of silicon single-photon avalanche diodes (SPADs) and in the design of associated electronic circuits. SPAD detectors with diameter up to 100 µm, good photon detection efficiency (48% peak at 550 nm wavelength) and low dark counting rate are used in these modules. Monolithic integrated active-quenching circuits (iAQC) and fast time-pickoff circuits ensure efficient photon counting and timing, with better than 50 ps FWHM time resolution and less than 50 ps centroid shift for counting rates up to 4 Mc/s. Experimental tests of the module performance and an application example are presented. [ABSTRACT FROM AUTHOR]
Details
- Language :
- English
- ISSN :
- 09500340
- Volume :
- 54
- Issue :
- 2/3
- Database :
- Academic Search Index
- Journal :
- Journal of Modern Optics
- Publication Type :
- Academic Journal
- Accession number :
- 24590982
- Full Text :
- https://doi.org/10.1080/09500340600763698