Back to Search Start Over

SNS Ring and RTBT Beam Current Monitor.

Authors :
Blokland, W.
Armstrong, G.
Deibele, C.
Pogge, J.
Gaidash, V.
Source :
AIP Conference Proceedings. 2006, Vol. 868 Issue 1, p238-245. 8p. 1 Color Photograph, 4 Diagrams, 2 Graphs.
Publication Year :
2006

Abstract

The SNS Diagnostics Group has implemented Beam Current Monitors (BCM) for the Ring and RTBT (Ring to Target Beam Transferline). In the Ring, the BCM must handle a thousand-fold increase of intensity during the accumulation, and in the RTBT, the BCM must communicate the integrated charge of the beam pulse in real-time for every shot to the target division for correlation with the produced neutrons. This paper describes the development of a four channel solution for the Ring BCM and the use of FPGA for the RTBT BCM to deliver the total charge to the target over a fiber optic network. Both system versions are based on the same commercial digitizer board. © 2006 American Institute of Physics [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
0094243X
Volume :
868
Issue :
1
Database :
Academic Search Index
Journal :
AIP Conference Proceedings
Publication Type :
Conference
Accession number :
23289382
Full Text :
https://doi.org/10.1063/1.2401410