Back to Search
Start Over
Investigation of Magnetic Fields in 1-MA Wire Arrays and X-Pinches.
- Source :
-
IEEE Transactions on Plasma Science . Oct2006 Part 3 Of 4, Vol. 34 Issue 5, p2247-2255. 9p. 16 Black and White Photographs, 7 Graphs. - Publication Year :
- 2006
-
Abstract
- A Faraday rotation diagnostic was applied for the investigation of magnetic fields in plasma of 1-MA wire arrays and X-pinches. Laser-probing diagnostics at the Zebra generator include a four-channel polarointerferometer and a four-frame shadowgraphy. The Faraday rotation diagnostic consists of shadow and Faraday channels, shearing air-wedge interferometer, and an additional schlieren channel. The implosion dynamics of the wire arrays were studied. A current in the plasma column of AI low-wire number arrays was found by the Faraday rotation diagnostic. Optical diagnostics showed a turbulent plasma and bubblelike objects in the plasma column of AI wire arrays. The Faraday rotation diagnostic demonstrated a complicated structure of magnetic fields in X-pinch plasma. [ABSTRACT FROM AUTHOR]
Details
- Language :
- English
- ISSN :
- 00933813
- Volume :
- 34
- Issue :
- 5
- Database :
- Academic Search Index
- Journal :
- IEEE Transactions on Plasma Science
- Publication Type :
- Academic Journal
- Accession number :
- 22979616
- Full Text :
- https://doi.org/10.1109/TPS.2006.877693