Back to Search Start Over

Giant Magnetoresistive Electrostatic Discharge Damage by a Surrounding Trigger.

Authors :
Long, Huojun
Tang, Xiong
Teng, Zhaoyu
Li, William
Chou, Sidney
Source :
IEEE Transactions on Magnetics. Feb2006 Part 1, Vol. 42 Issue 2, p237-240. 4p.
Publication Year :
2006

Abstract

Through an electrostatic discharge (ESD) damage case study of giant magnetoresistive (GMR) head in shunting process of head gimbal assemblies (HGA), this paper unveils that GMR heads would be damaged by a combination of field-induced voltage on HGA and surrounding trigger event. This investigation further demonstrates that the ESD protection technique, which derives from metal-to-metal contact to GMR terminals and thus focuses on eliminating metal-to-metal contact to GMR terminals, is not sufficient to prevent ESD. The electromagnetic interference caused by nearby trigger event needs to be noted also in the ESD control. [ABSTRACT FROM AUTHOR]

Details

Language :
Turkish
ISSN :
00189464
Volume :
42
Issue :
2
Database :
Academic Search Index
Journal :
IEEE Transactions on Magnetics
Publication Type :
Academic Journal
Accession number :
19935788
Full Text :
https://doi.org/10.1109/TMAG.2005.861740