Detectors with microchannel plates (MCPs) are currently widely used in photon and charged particle detection with high spatial (∼10 μm) and temporal (<0.5 ns) resolution. All the advances in MCP detection technologies can be successfully implemented for the detection of thermal neutrons by using MCPs manufactured from a modified glass mixture doped with neutron absorbing atoms. In this paper, we compare the efficiency of thermal neutron detection for two standard MCP geometries: circular-pore and square-pore MCPs doped with the 10B isotope. The results of our modeling indicate that the detection of thermal neutrons with a square-pore MCP is 11%-23% more efficient than for the circular geometry, and can be higher than 70% for the existing MCP technology. [ABSTRACT FROM AUTHOR]