Abstract

Background: Vibration-Controlled Transient Elastography (VCTE) with FibroScan is a non-invasive, reliable diagnostic tool for Metabolic-Dysfunction-Associated Steatotic Liver Disease (MASLD), enabling early detection and management to prevent severe liver diseases. VCTE's ease and portability suit primary care, streamlining referrals, promoting lifestyle changes, reducing costs, and benefiting underserved communities. Methods: Studies on point-of-care VCTE were systematically reviewed, followed by meta-analysis using a random-effects model. Pooled proportions with 95% confidence intervals were reported, and heterogeneity was assessed using I2%. Results: A total of twenty studies from 14 countries, including 6159 patients, were analyzed, with three studies from France, two from the U.S., and four from China. The population had a slight male preponderance, with a mean age range of 35–73 years and a BMI range of 24.4–41.1%. The diagnostic accuracy for detecting any fibrosis (≥F1) was reported in four studies (n = 210) with an AUC of 0.74, sensitivity of 69.5%, and specificity of 70.6%. For significant fibrosis (≥F2), eight studies (n = 650) reported an AUC of 0.69, sensitivity of 81.7%, and specificity of 64.6%. Advanced fibrosis (≥F3) was evaluated in 10 studies (n = 619), with an AUC of 0.84, sensitivity of 88.1%, and specificity of 63.8%. Cirrhosis (F4) was assessed in nine studies (n = 533), with an AUC of 0.65, sensitivity of 87.5%, and specificity of 62.6%. Steatosis diagnoses across stages S1 to S3 showed increasing diagnostic accuracies, with AUCs of 0.85, 0.76, and 0.80, respectively. Probe type and BMI were significant covariates influencing diagnostic performance for both fibrosis and steatosis, while the percentage of male participants also showed significant associations. Conclusions: VCTE shows high diagnostic accuracy for fibrosis and steatosis in MASLD patients at the point of care. Future research should assess its implementation in fibroscan settings. [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
20754418
Volume :
14
Issue :
22
Database :
Academic Search Index
Journal :
Diagnostics (2075-4418)
Publication Type :
Academic Journal
Accession number :
181171276
Full Text :
https://doi.org/10.3390/diagnostics14222478