Back to Search Start Over

Sensitive and selective determination of upadacitinib using a custom-designed electrochemical sensor based on ZnO nanoparticle-assisted molecularly imprinted polymer.

Authors :
Budak, Fatma
Çetinkaya, Ahmet
Atici, Esen Bellur
Ozkan, Sibel A.
Source :
Analytical & Bioanalytical Chemistry. Nov2024, Vol. 416 Issue 28, p6517-6527. 11p.
Publication Year :
2024

Abstract

Upadacitinib (UPA) is a selective and reversible oral Janus kinase (JAK) 1 inhibitor and is of great importance in treating inflammatory bowel disease (Zheng et al., Int Immunopharmacol 126:111229, 2024; Foy et al., JAAD Case Rep 42:20–22, 2023). Although there are limitations to the effectiveness of UPA, it has received positive responses in clinical trials and is approved for the treatment of atopy dermatitis (AD) (Li et al., Int Immunopharmacol 125:111193, 2023). In this study, a nanoparticle-doped molecularly imprinted polymer (MIP)-based electrochemical sensor was developed for sensitive and selective detection of UPA. The developed sensor was designed as a thin film layer using the photopolymerization method on the surface of the prepared nanoparticle-doped polymerization solution glassy carbon electrode (GCE). Various nanoparticles, such as multi-walled carbon nanotube, titanium dioxide, oxide, and zinc oxide (ZnO) nanoparticles, were the most suitable for UPA. Surface characterization of the developed sensor was done by scanning electron microscopy (SEM), and electrochemical characterization was done by cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS). The quantitative analysis of UPA was performed in 5.0 mM [Fe (CN)6]3−/4− solution using the differential pulse voltammetry (DPV) technique. Under optimum conditions, the calibration range was between 0.1 and 1 pM. The limit of detection (LOD) and limit of quantification (LOQ) were calculated as 0.005 pM and 0.017 pM, respectively. The sensor's accuracy was proven by performing a recovery study in serum. The sensor's selectivity was also evaluated using common interfering substances such as KNO3, CaCl2, Na2SO4, uric acid, ascorbic acid, dopamine, and paracetamol. According to the results obtained, the performance of the designed sensor was found to be quite sensitive and selective in determining UPA. The developed UPA-ZnO/3-APBA@MIP-GCE sensor showed high sensitivity and selectivity towards UPA. In addition, the selectivity, the most important feature of the MIP-based sensor, was confirmed by imprinting factor (IF) calculations using tofacitinib (TOF) and ruxolitinib (RUX). The sensor's unique selectivity is demonstrated by its successful performance even in the presence of UPA impurities. [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
16182642
Volume :
416
Issue :
28
Database :
Academic Search Index
Journal :
Analytical & Bioanalytical Chemistry
Publication Type :
Academic Journal
Accession number :
180734384
Full Text :
https://doi.org/10.1007/s00216-024-05541-0