Back to Search Start Over

Future energy landscapes: Analyzing the cost-effectiveness of nuclear-renewable integrated energy Systems in Retrofitting of coal power plants.

Authors :
Abdussami, Muhammad R.
Verma, Aditi
Source :
Applied Energy. Jan2025:Part A, Vol. 377, pN.PAG-N.PAG. 1p.
Publication Year :
2025

Abstract

Coal Power Plants (CPPs), despite their substantial contribution to global energy needs, pose significant environmental concerns due to Greenhouse Gas (GHG) emissions. Thus, the world has started thinking of alternative generation sources to replace CPPs. To replace CPPs, some energy generation resources must come into the scenario that can outshine the advantages of CPPs, such as easy availability of fuel, operational safety, and cost effectiveness. Concerning this matter, nuclear-renewable integrated systems can play a vital role as a potential replacement for CPPs. In this study, we systematically explore the transitional approach from CPPs to advanced energy systems and conduct an exhaustive comparative analysis focusing on three proposed energy system models: Greenfield, Coal-to-Nuclear (C2N), and Coal-to-Integrated Energy Systems (C2IES). Before conducting the comparative analysis, we determine the most feasible coal sites from Alaska, our surrogate location for this study, using a GIS-based nuclear reactor siting tool named "Siting Tool for Advanced Nuclear Development (STAND)." To carry out the comparative analysis among the proposed energy models for the selected coal site, we find out the optimal configuration of each system using a robust and recent nature-based metaheuristic optimization algorithm, Mountain Gazelle Optimization (MGO), complemented by another nature-based metaheuristic optimization algorithm, Particle Swarm Optimization (PSO), for validation. The key data used in this study include solar irradiance, temperature, wind speed, load profiles, and comprehensive cost data for each system component. Since the proposed energy models are highly complex and consider several assumptions, the key research findings are strengthened by performing a comprehensive sensitivity analysis. The base case results show that C2IES can reduce the Cost of Energy (COE) by roughly 65 % compared to Greenfield and C2N and ensure the utmost reliability of the energy system. Although this cost-saving margin contrasts in the sensitivity analysis across a range of scenarios, C2IES consistently offers the most cost-effective solution, highlighting its potential for sustainable energy transition. • First-of-its-kind research on the techno-economic evaluation of transitioning from CPPs to IESs. • Mathematical modeling and analysis of Greenfield, C2N, and C2IES energy models. • C2IES model includes renewables, cutting COE by three times compared to Greenfield and C2N. • Baseline scenarios assessed through extensive sensitivity analysis, confirming key findings. [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
03062619
Volume :
377
Database :
Academic Search Index
Journal :
Applied Energy
Publication Type :
Academic Journal
Accession number :
180730416
Full Text :
https://doi.org/10.1016/j.apenergy.2024.124460