Back to Search Start Over

Validation and Analysis of an Integrated Device for Recording Bite Force and Masseter Muscle Activity in Dentate Participants: An Observational Study.

Authors :
MANI, UMAMAHESWARI
ARUN, AISHWARYA
MOHAMED, KASIM
Source :
Journal of Clinical & Diagnostic Research. Oct2024, Vol. 18 Issue 10, p28-33. 6p.
Publication Year :
2024

Abstract

Introduction: The success of any prosthetic rehabilitation depends on acceptable occlusion and muscle coordination. Occlusal therapy should be an integral part of restorative and prosthetic treatment. A thorough diagnosis of bite force and muscle activity is required to ensure the patient's masticatory function and comfort. The current system of digitisation lacks devices for the simultaneous evaluation of muscle activity and occlusal bite force, representing a significant limitation in understanding and managing restorative and rehabilitation therapy. Aim: To assess the efficacy of an ingeniously designed integrated device that records occlusal bite force and muscle activity. Materials and Methods: An observational study was conducted among 112 healthy volunteers in the Department of Prosthodontics at Sri Ramachandra Dental College and Hospital, Chennai, Tamil Nadu, India, for a period of one month and 45 days, from February 5, 2024 to March 20, 2024. The study aimed to validate the efficacy of a device designed to record bite force and muscle action potential simultaneously. The device consists of two key components: a square Forcesensitive Resistor (FSR) that records changes in resistance in response to applied force and a MyoWare 2.0 muscle sensor with Arduino (Advancer Technologies) for measuring the electrical activity of muscles. Study participants, aged between 21 and 35 years, were seated in an upright position. Muscle activity was recorded with surface electrodes placed on the masseter region, following Surface Electromyography for the Non Invasive Assessment of Muscles (SENIAM) guidelines, while a ground electrode was placed on the neck. Maximum Bite Force (MBF) was measured by placing intraoral pressure sensors, with recordings taken in maximum intercuspation three times, spaced one minute apart for each recording. Both muscle activity and bite force were recorded simultaneously. The Pearson's correlation coefficient was used to evaluate the correlation between bite forces and muscle action potential with standard average values. Results: The results revealed a strong positive correlation between the masseter muscle activity action potential and the bite force values of the right molar (r=0.964, p<0.001), left molar (r=0.980, p<0.001) and incisor (r=0.550, p=0.002). Conclusion: The device synergistically records muscle activation patterns and bite force distribution, displaying the values in an integrated digital interface. The results of the study reveal that this device can serve as a diagnostic tool in prosthodontic treatment planning. [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
0973709X
Volume :
18
Issue :
10
Database :
Academic Search Index
Journal :
Journal of Clinical & Diagnostic Research
Publication Type :
Academic Journal
Accession number :
180690066
Full Text :
https://doi.org/10.7860/JCDR/2024/71177.20147