Back to Search Start Over

A Framework for Promoting Passive Breast Cancer Monitoring: Deep Learning as an Interpretation Tool for Breast Thermograms.

Authors :
Firouzmand, Mohamad
Majidzadeh, Keivan
Jafari, Maryam
Haghighat, Shahpar
Esmaeili, Rezvan
Moradi, Leila
Misaghi, Nima
Ensafi, Mahsa
Batmanghelich, Fatemeh
Keyvanpour, Mohammad Reza
Shojaedini, Seyed Vahab
Source :
Iranian Journal of Medical Physics / Majallah-I Fīzīk-I Pizishkī-i Īrān. Jul/Aug2024, Vol. 21 Issue 4, p237-248. 12p.
Publication Year :
2024

Abstract

Introduction: Several types of cancer can be detected early through thermography, which uses thermal profiles to image tissues in recent years, thermography has gained increasing attention due to its non-invasive and radiation-free nature. There is a growing need for thermographic images of breast cancer lesions in different nationalities and ages to develop this technique, however. This study aims to introduce a dataset of breast thermograms. Material and Methods: In this study, thermographic images of breast cancer from Iranian samples were prepared and confirmed due to the limited number of breast thermogram databases. The prepared database was tested using artificial intelligence and another well-known DMR database (Database for Mastology Research) in this study to determine its reliability. Results: A variety of deep learning architectures and transfer learning are used to evaluate these databases for accuracy, sensitivity, speed, training compliance, and validation compliance. According to best-fitted structures for both types of databases, the database obtained from this study has a quality comparable to the DMR reference database, with minimum accuracy, sensitivity, specificity, precision, and F-score of 80%, 86%, 86%, 88%, and 87%, respectively. Conclusion: Using thermography as a method of early breast screening is demonstrated to be effective. In comparison to DMR, the lower statistics of the proposed database (between 2 and 7 percent) indicates that more diverse breast thermograms should be captured in conjunction with improvements to imaging equipment as well as adherence to thermography recording protocols in order to improve the reliability and efficiency of the database. [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
1735160X
Volume :
21
Issue :
4
Database :
Academic Search Index
Journal :
Iranian Journal of Medical Physics / Majallah-I Fīzīk-I Pizishkī-i Īrān
Publication Type :
Academic Journal
Accession number :
180511475
Full Text :
https://doi.org/10.22038/ijmp.2023.71683.2268