Back to Search
Start Over
Enhancing acute stroke assessment: evaluating the clinical utility of the "Real" one-stop-shop scan protocol combining brain computed tomography perfusion and head-and-neck computed tomography angiography using a 512-slice detector computed tomography scanner
- Source :
-
Clinical Radiology . Nov2024, Vol. 79 Issue 11, p833-841. 9p. - Publication Year :
- 2024
-
Abstract
- To assess the efficiency and diagnostic value of the "real" one-stop-shop protocol integrating the computed tomography angiography (CTA) sequence of the head and neck into the computed tomography perfusion (CTP) acquisition using a 512-slice detector CT scanner in patients who suffered from acute ischemic stroke. This prospective study included 100 patients suspected of acute ischemic stroke. The patients were randomly divided into two groups: the control group (n=50) who underwent the traditional protocol (brain CTP and head-and-neck CTA examination separately) and the experimental group (n=50) who underwent a one-stop-shop protocol (combined brain CT perfusion and head-and-neck CTA, the CTA triggering time determined by a low-dose test bolus injection). The examination time, contrast-agent dosage, radiation dose, postprocessing time, and image quality were compared between the two groups. Compared to the control group, the experimental group had a significantly lower total iodine contrast-agent dosage (80 vs. 100 ml, P <0.001) and shorter scan time (3.23 [3.13, 3.35] vs. 2.32 [2.17, 2.45] min, P <0.001). Additionally, the radiation dose exposure was lower in the experimental group than in the control group (5129.00 [5173, 5232] vs. 4681.35 [4555.12, 4822.95] mGy-cm, P <0.001). No statistically significant differences were observed between the two groups in terms of postprocessing time, head-and-neck CTA, and CTP imaging quality. The one-stop-shop protocol enables effective detection of lesions, providing clear visualization of the location and degree of stenosis in the head-and-neck vessels. It achieves this with lower costs in scan time, contrast-agent dosage, and radiation dose compared to the traditional protocol and is thus worth considering as the first examination for patients who suffer from acute ischemic stroke. • The one-stop-shop solution integrates CTA sequence into CTP acquisition protocol. • The one-stop-shop protocol eliminates the need for two injections of contrast agents. • The shorter scanning time, radiation exposure, and lower contrast-agent dosages. • The one-stop-shop protocol provides high-quality images. [ABSTRACT FROM AUTHOR]
Details
- Language :
- English
- ISSN :
- 00099260
- Volume :
- 79
- Issue :
- 11
- Database :
- Academic Search Index
- Journal :
- Clinical Radiology
- Publication Type :
- Academic Journal
- Accession number :
- 180175710
- Full Text :
- https://doi.org/10.1016/j.crad.2024.07.023