Back to Search Start Over

Investigation on Overvoltage Distribution in Stator Windings of Permanent Magnet Synchronous Wind Turbines.

Authors :
Li, Shulin
Tian, Fuqiang
He, Haitao
Liu, Hongqi
Zhang, Shifu
Li, Yudi
Source :
Energies (19961073). Sep2024, Vol. 17 Issue 17, p4255. 15p.
Publication Year :
2024

Abstract

The PWM voltage pulses output by the inverter reaches the stator winding of the wind turbine generator through the cable. Due to the impedance mismatch between the motor and the cable, the voltage at the motor end rises under the action of the circuit wave process; on the other hand, electromagnetic oscillation occurs within the motor winding. Higher overvoltage is generated under the combined effect of both, which greatly accelerates the aging and breakdown of the insulation layer of the permanent magnet synchronous wind turbine. In this paper, a three-dimensional electromagnetic model of the permanent magnet synchronous wind turbine generator is established. The distribution circuit parameters of the stator winding of the permanent magnet machine are calculated using the finite element method, and its circuit model is based. The voltage distribution of the stator winding under different PWM excitations is investigated by simulation software, and the effects of the time of the rising edge and the pulse width of the PWM pulse on the stator winding voltage to ground and the turn-to-turn voltage distribution are studied. The results show that the effect of the rising edge time is larger when the rising edge time is shorter, the maximum voltage to ground occurs in the first coil, and the amplitude can be up to 1.5 times of the output voltage. When the rising edge time is longer, the maximum voltage to ground occurs in the end coil, and the amplitude is slightly higher than the output voltage. The trend of turn-to-turn voltage variation is similar for different rising edges; only the maximum turn-to-turn voltage amplitude is different. Pulse width has a small effect on overvoltage and only occurs when the pulse width is less than 10 μs. The research results of this paper are of great significance in revealing the aging and breakdown mechanism of the generator stator insulation, as well as the insulation coordination and design. [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
19961073
Volume :
17
Issue :
17
Database :
Academic Search Index
Journal :
Energies (19961073)
Publication Type :
Academic Journal
Accession number :
179644972
Full Text :
https://doi.org/10.3390/en17174255