Back to Search Start Over

Comparative Study of Raman and EPMA Elemental Mapping of an Unirradiated MOX Sample.

Authors :
Colle, Jean-Yves
Pöml, Philipp
Boshoven, Jacobus
Konings, Rudy J. M.
Source :
Nuclear Technology. Sep2024, p1-8. 8p. 8 Illustrations, 3 Charts.
Publication Year :
2024

Abstract

AbstractThe distribution of U and Pu of a mixed-oxide fuel sample is analyzed by Raman spectroscopy and electron probe microanalysis, with the goal of comparing the distribution maps from the two techniques. Qualitatively, the maps reveal the same features of Pu-rich agglomerates and the near Pu-free UO2 matrix, and the differences between the derived absolute concentrations are within 10%. Differences are likely due to a shift in the Raman signal originating from the local stoichiometry variation or self-irradiation damage. [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
00295450
Database :
Academic Search Index
Journal :
Nuclear Technology
Publication Type :
Academic Journal
Accession number :
179431394
Full Text :