Failure investigation of an elbow pipe used in sewage water treatment facility.

Authors :
Garg, Siddharth
Bansal, Sourabh
Murtaza, Qasim
Source :
Materials & Corrosion / Werkstoffe und Korrosion. Sep2024, Vol. 75 Issue 9, p1185-1192. 8p.
Publication Year :
2024

Abstract

In this research work, a real case of failed ASTM A860 WPHY 65 long elbow pipe coated with inorganic zinc ethyl silicate primer is collected from a treatment facility to investigate the root causes of its failure, which was reported after approximately 28 months of use. The failure was investigated using visual observations, metallurgical analysis using optical emission spectroscopy, mechanical testing, X‐ray diffraction of corrosion product, chemical analysis of sewage and corrosion rate test of the elbow using a three‐electrode potential technique, fractographic analysis using scanning electron microscope along with computational analysis to confirm the results. Through the testing, it was observed that severe depletion in the strength can be attributed to erosion–corrosion caused by various impurities present in the sewage, leading to the generation of corrosion pits and turbulent eddies and stresses generated due to sudden changes in fluid flow direction along with gases present in sewage reacting with a base metal. Various failure mechanisms that have led to pipe failure are discussed in this paper, along with a listing of preventive measures to delay it. [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
09475117
Volume :
75
Issue :
9
Database :
Academic Search Index
Journal :
Materials & Corrosion / Werkstoffe und Korrosion
Publication Type :
Academic Journal
Accession number :
179393413
Full Text :
https://doi.org/10.1002/maco.202414336