Abstract
- SPARC will be outfitted with three systems of x-ray crystal spectrometer arrays. Two of these are designed using cylindrically bent crystals to achieve high spectral-resolution for ion temperature and toroidal velocity measurements via imaging He-like Kr and Ne-like Xe. The last acts as a spectral survey system to monitor Ne-like W and nearby H- and He-like emission from Cr, Fe, Co, Ni, and Cu. Line radiation intensities are calculated using the Flexible Atomic Code for atomic data and ColRadPy for collisional-radiative modeling, then convoluted with a Voigt line shape. Freeāfree, free-bound, and two-photon continuum radiation is also included. The ToFu code is used to perform volume-of-sight integration to produce synthetic detector images. In addition, presented is cross-validation performed using the XICSRT Monte Carlo ray-tracing code. Ion temperature and toroidal velocity profiles are reconstructed using ToFu via tomographic inversion. [ABSTRACT FROM AUTHOR]