Back to Search Start Over

Preparation of radiation-sensitive dosimeter for gamma rays.

Authors :
Gafar, S. M.
El-Tokhy, H. H.
Source :
Journal of Radioanalytical & Nuclear Chemistry. Aug2024, Vol. 333 Issue 8, p3997-4004. 8p.
Publication Year :
2024

Abstract

This research uses two different dosimetry techniques (films and gels) to evaluate how γ-rays affect Cyanidin chloride. The first method relies on combining CC with poly (vinyl alcohol) to create a thin film dosimeter, while the second uses CC with gelatin to create a gel dosimeter that is more sensitive to γ-rays. The produced film or gel changes visually from red to colorless when exposed to γ-rays. The usable dose range of films was up to 35 kGy, and for gels, it was between 10 and 150 Gy. All dosimetric characteristics were studied. [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
02365731
Volume :
333
Issue :
8
Database :
Academic Search Index
Journal :
Journal of Radioanalytical & Nuclear Chemistry
Publication Type :
Academic Journal
Accession number :
179231502
Full Text :
https://doi.org/10.1007/s10967-024-09560-0