Demand response through ventilation and latent load adjustment for commercial buildings in humid climate zones.

Authors :
Ma, Zhihao
Cui, Shuang
Chen, Jianli
Source :
Applied Energy. Nov2024, Vol. 373, pN.PAG-N.PAG. 1p.
Publication Year :
2024

Abstract

Space cooling constitutes >10% of worldwide electricity consumption and is anticipated to rise swiftly due to intensified heatwaves under emerging climate change. The escalating electricity demand for cooling services will challenge already stressed power grids, especially during peak times of demand. To address this, the adoption of demand response to adjust building energy use on the end-user side becomes increasingly important to adapt future smart buildings with rapidly growing renewable energy sources. However, existing demand response strategies predominantly explore sensible cooling energy as flexible building load while neglecting latent cooling energy, which constitutes significant portions of total energy use of buildings in humid climates. Hence, this paper aims to evaluate the demand response potential by adjusting latent cooling energy through ventilation control for typical medium commercial office buildings in four representative cities across different humid climate zones, i.e. , Miami, Huston, Atlanta, and New York in the United States (US). As the first step, the sensible heat ratio, defined as sensible cooling load to total building load (involving both sensible and latent load), in different humid climates are calculated. Subsequently, the strategy to adjust building latent load through ventilation control (LLVC) is explored and implemented for demand response considering the balance of energy shifting, indoor air quality, and energy cost. Results reveal that adjusting building ventilation is capable of achieving 30%–40% Heating, Ventilation, and Air-conditioning (HVAC) cooling demand flexibility during HVAC operation while among this, the latent cooling energy contributes 56% ∼ 66.4% to the overall demand flexibility. This work provides a feasible way to improve electricity grid flexibility in humid climates, emphasizing the significant role of adjusting latent cooling energy in building demand response. • Utilize EnergyPlus to evaluate the latent cooling load of commercial buildings in humid climate zones. • Propose a latent load adjustment strategy through ventilation control for building energy demand response. • Compare the flexibility of sensible to latent cooling load by adjusting setpoint of air-conditioning. [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
03062619
Volume :
373
Database :
Academic Search Index
Journal :
Applied Energy
Publication Type :
Academic Journal
Accession number :
179065023
Full Text :
https://doi.org/10.1016/j.apenergy.2024.123940