Back to Search Start Over

Wireless implantable bioelectronics with a direct electron transfer lactate enzyme for detection of surgical site infection in orthopaedics.

Authors :
Gil, Bruno
Hall, Thomas A.G.
Freeman, David M.E.
Ming, Damien
Kechagias, Stylianos
Nabilla, Sasza
Cegla, Frederic
van Arkel, Richard J.
Source :
Biosensors & Bioelectronics. Nov2024, Vol. 263, pN.PAG-N.PAG. 1p.
Publication Year :
2024

Abstract

Periprosthetic infection is one of the most devastating complications following orthopaedic surgery. Rapid detection of an infection can change the treatment pathway and improve outcomes for the patient. In here, we propose a miniaturized lactate biosensor developed on a flexible substrate and integrated on a small-form bone implant to detect infection. The methods for lactate biosensor fabrication and integration on a bone implant are fully described within this study. The system performance was comprehensively electrochemically characterised, including with L-lactate solutions prepared in phosphate-buffered saline and culture medium, and interferents such as acetaminophen and ascorbic acid. A proof-of-concept demonstration was then conducted with ex vivo ovine femoral heads incubated with and without exposure to Staphylococcus epidermidis. The sensitivity, current density and limit-of-detection levels achieved by the biosensor were 1.25 μA mM−1, 1.51 μA.M−1.mm−2 and 66 μM, respectively. The system was insensitive to acetaminophen, while sensitivity to ascorbic acid was half that of the sensitivity to L-lactate. In the ex vivo bone model, S. epidermidis infection was detected within 5 h of implantation, while the control sample led to no change in the sensor readings. This pioneering work demonstrates a pathway to improving orthopaedic outcomes by enabling early infection diagnosis. • Flexible lactate sensor with direct electron transfer using a 3rd-generation enzyme. • Biosensor testing against lactate solutions in PBS/culture medium and interferents. • Biosensor integration in a bone implant for detection of infection in orthopaedics. • Low-powered implant bioelectronics with wireless data readings of lactate levels. • E x vivo detection in ovine femoral heads infected by Staphylococcus epidermidis. [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
09565663
Volume :
263
Database :
Academic Search Index
Journal :
Biosensors & Bioelectronics
Publication Type :
Academic Journal
Accession number :
178998616
Full Text :
https://doi.org/10.1016/j.bios.2024.116571