Back to Search Start Over

Impact of Preprocessing Parameters in Medical Imaging-Based Radiomic Studies: A Systematic Review.

Authors :
Trojani, Valeria
Bassi, Maria Chiara
Verzellesi, Laura
Bertolini, Marco
Source :
Cancers. Aug2024, Vol. 16 Issue 15, p2668. 17p.
Publication Year :
2024

Abstract

Simple Summary: This review investigates how preprocessing parameters are related to the reproducibility and reliability of radiomic features derived from multimodality imaging techniques such as computed tomography (CT), magnetic resonance imaging (MRI), cone-beam CT (CBCT), and positron emission tomography (PET)/CT. Radiomics, which involves extracting quantitative features from medical images, shows great potential as a source of non-invasive clinical biomarkers but is hindered by variability in imaging parameters, especially during acquisition, reconstruction, and preprocessing. Standardizing and reporting preprocessing procedures is essential for consistent extraction of radiomic features, given their significant role in determining the robustness and reproducibility of these features. Background: Lately, radiomic studies featuring the development of a signature to use in prediction models in diagnosis or prognosis outcomes have been increasingly published. While the results are shown to be promising, these studies still have many pitfalls and limitations. One of the main issues of these studies is that radiomic features depend on how the images are preprocessed before their computation. Since, in widely known and used software for radiomic features calculation, it is possible to set these preprocessing parameters before the calculation of the radiomic feature, there are ongoing studies assessing the stability and repeatability of radiomic features to find the most suitable preprocessing parameters for every used imaging modality. Materials and Methods: We performed a comprehensive literature search using four electronic databases: PubMed, Cochrane Library, Embase, and Scopus. Mesh terms and free text were modeled in search strategies for databases. The inclusion criteria were studies where preprocessing parameters' influence on feature values and model predictions was addressed. Records lacking information on image acquisition parameters were excluded, and any eligible studies with full-text versions were included in the review process, while conference proceedings and monographs were disregarded. We used the QUADAS-2 (Quality Assessment of Diagnostic Accuracy Studies 2) tool to investigate the risk of bias. We synthesized our data in a table divided by the imaging modalities subgroups. Results: After applying the inclusion and exclusion criteria, we selected 43 works. This review examines the impact of preprocessing parameters on the reproducibility and reliability of radiomic features extracted from multimodality imaging (CT, MRI, CBCT, and PET/CT). Standardized preprocessing is crucial for consistent radiomic feature extraction. Key preprocessing steps include voxel resampling, normalization, and discretization, which influence feature robustness and reproducibility. In total, 44% of the included works studied the effects of an isotropic voxel resampling, and most studies opted to employ a discretization strategy. From 2021, several studies started selecting the best set of preprocessing parameters based on models' best performance. As for comparison metrics, ICC was the most used in MRI studies in 58% of the screened works. Conclusions: From our work, we highlighted the need to harmonize the use of preprocessing parameters and their values, especially in light of future studies of prospective studies, which are still lacking in the current literature. [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
20726694
Volume :
16
Issue :
15
Database :
Academic Search Index
Journal :
Cancers
Publication Type :
Academic Journal
Accession number :
178952287
Full Text :
https://doi.org/10.3390/cancers16152668