Back to Search Start Over

A clinical comparison of glycol and water-based heater-cooler systems for cardiopulmonary bypass.

Authors :
Ohlrich, Kelly
Kwon, Jennie
Hill, Morgan A
Ayala, McKenzie
Stone, Amber
Bruner, Samantha
Pollard, Melissa
Dell’Aiera, Laura
Fitzgerald, David
Kilic, Arman
Source :
Perfusion. Aug2024, p1.
Publication Year :
2024

Abstract

While newer heater-cooler technologies using ethylene glycol-based (GB) solutions during cardiothoracic surgery have become commercially available, there is a paucity of clinical data describing their effectiveness during cardiopulmonary bypass (CPB) support. This analysis aimed to compare clinical characteristics and procedural outcomes using water-based (WB) and GB heater-cooler systems.A retrospective analysis was performed on consecutive adult patients undergoing CPB from June to October 2022 comparing WB or GB groups. The primary outcome was a composite of operative death or major morbidity. Secondary endpoints included transfusion requirements on CPB, patient cooling and warming rates, and vasoactive-inotropic scores (VIS) at case completion. P-control charts were used to monitor the weekly incidence of the composite outcome. A sub-analysis was performed to evaluate the primary outcome for cardiac surgery cases indexed by the Society of Thoracic Surgeons (STS).There were 167 patients included for analysis; 87 (52.1%) underwent CPB with a WB system and 80 (47.9%) with a GB system. GB procedure subjects were younger (<italic>p</italic> = .01), experienced longer CPB times (<italic>p</italic> = .034), and were more likely to receive thoracic transplant or aortic surgery (<italic>p</italic> = 0.015). The composite outcome of operative mortality or major morbidity occurred in 29.9% and 24% of the WB and GB groups, respectively (<italic>p</italic> = .372). P-control charts indicated a weekly mean incidence of 30% during WB practice, which decreased to 24% with GB practice. Among 106 STS-indexed cardiac surgery cases, mean composite outcome incidence decreased from 19% to 6% following our GB transition. Additionally, cooling, and warming rates indexed to patient BSA and VIS at case completion were not significantly different.Our analysis demonstrated a safe transition from WB to GB heater-cooler technologies in our practice. This early analysis suggests that GB heater coolers may be safely adopted to mitigate the risks of nontuberculous mycobacterium infections for cardiac surgical patients. [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
02676591
Database :
Academic Search Index
Journal :
Perfusion
Publication Type :
Academic Journal
Accession number :
178871902
Full Text :
https://doi.org/10.1177/02676591241270961