Back to Search Start Over

Temperature Evaluation Considering Gradient Distribution for MV Cable XLPE Insulation Based on Wave Velocity.

Authors :
Liu, Yan
Liu, Jianben
Zhang, Longxiang
Liang, Yuwei
Zhong, Yuyao
Li, Yan
Source :
Symmetry (20738994). Jul2024, Vol. 16 Issue 7, p834. 14p.
Publication Year :
2024

Abstract

Temperature is an important factor for the service life of cable insulation. To ensure safety, the operating temperature of cables must be monitored. Since optical fiber temperature measurement technology is difficult to be used widely in medium voltage (MV) cables due to cost, this paper proposes a temperature evaluation method based on wave velocity. Firstly, the dielectric constant of cross-linked polyethylene (XLPE) cable insulation under different temperature is obtained through experiment. Based on the result, the relationship curve between wave velocity and temperature is established. The asymmetry effect due to temperature gradient in the cable insulation is discussed via finite element simulation. The effectiveness of obtaining the average insulation temperature of the cable based on wave velocity is validated. In addition, the mechanism of the temperature influence on the cable insulation material's dielectric constant is analyzed by molecular dynamics simulation, which further deepens understanding of the characteristics of cable insulation materials. [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
20738994
Volume :
16
Issue :
7
Database :
Academic Search Index
Journal :
Symmetry (20738994)
Publication Type :
Academic Journal
Accession number :
178695551
Full Text :
https://doi.org/10.3390/sym16070834