Effectiveness of Clear Aligners on Sequential Maxillary Molar Distalization: Discrepancy between Treatment Goal and Outcome.
- Source :
-
Journal of Clinical Medicine . Jul2024, Vol. 13 Issue 14, p4216. 14p. - Publication Year :
- 2024
-
Abstract
- Objectives: The purpose of this preliminary study was to determine the differences between planned and actual maxillary molar movements after the completion of treatment with an initial set of clear aligners including sequential maxillary molar distalization. Methods: The data records of 14 non-growing patients who completed orthodontic treatment with sequential maxillary molar distalization using clear aligners were retrospectively evaluated (n= 14, 4 males and 10 females, 33.61 ± 8.57 years). Data on planned tooth movements were obtained from ClinCheck software (ClinCheck Pro version 5.3). The amounts of actual tooth movements were obtained by performing superimposition of lateral cephalograms taken before and after treatment. The amounts of distal translation and tipping between planned and actual maxillary molar movements were compared with the paired Student's t-test. Results: The statistically significant differences between planned and actual translation movements of maxillary first and second molars were shown after completing treatment with the first series of aligners (p < 0.05). The average actual amount of molar distalization on maxillary first molars was less than the planned amount by 1.32 ± 0.42 mm. Similarly, the average actual amount of molar distalization on maxillary second molars was less than the planned amount by 1.57 ± 0.45 mm. The accuracy for molar distalization, namely, the percentage of actual distal translation to planned movement, was 40.11% for maxillary first molars and 35.39% for maxillary second molars. However, the difference between the planned and actual angulation movements was not significant (p > 0.05). Conslusions: In conclusion, the amounts of actual distal translation of maxillary molars through the utilization of clear aligners were significantly lower than planned. However, there were no statistically significant differences between the degrees of actual and planned molar angulation movement. [ABSTRACT FROM AUTHOR]
- Subjects :
- *MOLARS
*ORTHODONTIC appliances
*CORRECTIVE orthodontics
*TEETH
*FEMALES
Subjects
Details
- Language :
- English
- ISSN :
- 20770383
- Volume :
- 13
- Issue :
- 14
- Database :
- Academic Search Index
- Journal :
- Journal of Clinical Medicine
- Publication Type :
- Academic Journal
- Accession number :
- 178693243
- Full Text :
- https://doi.org/10.3390/jcm13144216