Time evolution of rejected, coincidence spectra, registered on germanium gamma spectrometers with muon-sensitive veto shields.
- Source :
-
Journal of Radioanalytical & Nuclear Chemistry . Jul2024, Vol. 333 Issue 7, p3529-3539. 11p. - Publication Year :
- 2024
-
Abstract
- This paper presents the effects of background reduction with anticoincidence logical condition between the sum of muon-sensitive large scintillator veto detectors and a germanium detector as well as the time evolution of rejected, muon-induced coincidence gamma spectra. A special attention is paid to neutron effects. The digital event-by-event registration used for data acquisition opens possibilities to study in an off-line mode the variety of effects related to the time structure of all signals registered by detectors. In our laboratory currently we use two such systems with in-house written software Veto for off-line data analysis. [ABSTRACT FROM AUTHOR]
Details
- Language :
- English
- ISSN :
- 02365731
- Volume :
- 333
- Issue :
- 7
- Database :
- Academic Search Index
- Journal :
- Journal of Radioanalytical & Nuclear Chemistry
- Publication Type :
- Academic Journal
- Accession number :
- 178483197
- Full Text :
- https://doi.org/10.1007/s10967-024-09412-x