Back to Search Start Over

Design of a Cavity for the High-Power Radio-Frequency Quadrupole Coupler Test for the ANTHEM Project.

Authors :
Passarelli, Andrea
Masullo, Maria Rosaria
Baltador, Carlo
Grespan, Francesco
Palmieri, Antonio
Pisent, Andrea
Mereu, Paolo
Mingioni, Carlo
Nenni, Marco
Nicoletti, Edoardo
Source :
Sensors (14248220). Jul2024, Vol. 24 Issue 13, p4165. 15p.
Publication Year :
2024

Abstract

The ANTHEM (Advanced Technologies for Human-centered Medicine) Radio-Frequency Quadrupole (RFQ) will employ eight coaxial power couplers, which will be magnetically coupled to the device through a loop antenna. The coupler design can support up to 140 kW in continuous wave operation. This paper presents the design of the cavity used for high-power testing, with the primary objectives of both optimizing the coupling between the couplers and ensuring operations at the designated operating frequency. Furthermore, the paper encompasses thermal and structural assessments conducted through numerical simulations. [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
14248220
Volume :
24
Issue :
13
Database :
Academic Search Index
Journal :
Sensors (14248220)
Publication Type :
Academic Journal
Accession number :
178413363
Full Text :
https://doi.org/10.3390/s24134165