Abstract
- Geothermal Power Plant is a power plant that utilizes geothermal fluids as its main source. Pressure Loss is a description of pressure loss at a point in the pipe caused by elevation. With the loss of pressure from pond to pond has elevation, a pump is needed to increase fluid flow. The pump used is a stage 7 pump. Therefore, a pressure loss analysis was carried out from pond to pond (balong) using the Harrison-Freeston correlation method to determine how much pressure loss was significant. From this method, that for the initial pressure in the injection well is 21 bar and for the pressure loss value of 0.06025481 bar [ABSTRACT FROM AUTHOR]