Back to Search
Start Over
Low-energy Auger and conversion electron spectroscopy of 99Mo [formula omitted]-decay.
- Source :
-
Applied Radiation & Isotopes . Sep2024, Vol. 211, pN.PAG-N.PAG. 1p. - Publication Year :
- 2024
-
Abstract
- The preparation of nanometer-thick molybdenum-99 (99Mo) sources using the droplet deposition method was investigated. The quality of these prepared sources was analyzed using scanning electron microscopy (SEM), electron Rutherford backscattering (ERBS) techniques, and Geant4 simulations. The emitted electrons resulting from the β − -decay of the prepared 99Mo sources, with energies below 2.2 keV, were measured and compared with existing literature data as well as the results obtained from our in-house Monte-Carlo model, BrIccEmis. • Auger electron spectroscopy of medical isotopes. • Electron spectroscopy. • Low energy. • High resolution. [ABSTRACT FROM AUTHOR]
Details
- Language :
- English
- ISSN :
- 09698043
- Volume :
- 211
- Database :
- Academic Search Index
- Journal :
- Applied Radiation & Isotopes
- Publication Type :
- Academic Journal
- Accession number :
- 178358104
- Full Text :
- https://doi.org/10.1016/j.apradiso.2024.111405