Development of a plastic scintillator based and SiPM readout detector for high-precision fast-timing measurements at rosphere array.
- Source :
-
Nuclear Instruments & Methods in Physics Research Section A . Aug2024, Vol. 1065, pN.PAG-N.PAG. 1p. - Publication Year :
- 2024
-
Abstract
- We report on the development of a custom particle detection system that aims to improve the detection capabilities of the ROSPHERE array. The detector is designed specifically for lifetime measurements using the in-beam Fast-timing method for nuclear states in nuclides produced in nuclear transfer reactions. An 80 x 3.6 mm disc of BC400 plastic scintillator was coupled to a sparse SiPM array readout connected to a dedicated Front End Electronics board. The detector was tested versus a conical LaBr 3 (Ce) coupled to a Hamamatsu PMT readout. The timing measurements resulted in a resolution of 896(5) ps. The detector design, characteristics, and performances are presented in this paper along with future improvements. [ABSTRACT FROM AUTHOR]
Details
- Language :
- English
- ISSN :
- 01689002
- Volume :
- 1065
- Database :
- Academic Search Index
- Journal :
- Nuclear Instruments & Methods in Physics Research Section A
- Publication Type :
- Academic Journal
- Accession number :
- 178334803
- Full Text :
- https://doi.org/10.1016/j.nima.2024.169495