Back to Search Start Over

Development of a Leak Detector of Methane Based on Absorption Spectroscopy Using Diode Matrixes.

Authors :
Boyko, A. A.
Kiryakova, A. Yu.
Erushin, E. Yu.
Kostyukova, N. Yu.
Source :
Instruments & Experimental Techniques. Apr2024, Vol. 67 Issue 2, p358-363. 6p.
Publication Year :
2024

Abstract

The article is devoted to the study of a methane leak detector based on absorption spectroscopy. An LED matrix with a wavelength of ~3.3 μm was used as a radiation source, where one of the methane absorption lines is located. The system is temperature stabilized. A threshold sensitivity of approximately 60 ppm CH4 was obtained. [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
00204412
Volume :
67
Issue :
2
Database :
Academic Search Index
Journal :
Instruments & Experimental Techniques
Publication Type :
Academic Journal
Accession number :
178316512
Full Text :
https://doi.org/10.1134/S0020441224700374