Should a low starting point be abandoned for cannulated screw fixation of femoral neck fractures?

Authors :
Wodarek, Jeremy
Ostrander, James
Atkinson, Patrick
Atkinson, Theresa
Source :
Computer Methods in Biomechanics & Biomedical Engineering. Jun2024, p1-13. 13p. 6 Illustrations.
Publication Year :
2024

Abstract

AbstractA validated femoral neck fracture model stabilized with three inverted cannulated screws was used to consider different intraoperative scenarios when the inferior screw hole is inadvertently started too inferiorly. These scenarios were to: (1) abandon the misplaced inferior screw hole and restart this hole more proximally, or (2) accept the mispositioned placement of the inferior screw and insert the remaining superior screws parallel or convergent to the inferior screw. Utilizing the second option and accepting the errant hole was associated with the greatest interfragmentary motion and stresses in the bone and hardware. In contrast, the first option created an improved mechanical environment for healing. [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
10255842
Database :
Academic Search Index
Journal :
Computer Methods in Biomechanics & Biomedical Engineering
Publication Type :
Academic Journal
Accession number :
178173836
Full Text :
https://doi.org/10.1080/10255842.2024.2372619